Cement_Slurry_Pty_Set


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Cement_Slurry_Pty_Set
Entity Type Table
Description A set of properties collected during a test performed on a batch of cement slurry
Submodel Cementing
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Average_Foam_Density double Density
g/cm3
Average density of the foam No
NUMBER
Cement_Slurry_Test_Id Cement_Slurry_Test
The test that produced the properties of the cement slurry No
NUMBER(38)
Density double Density
g/cm3
The density of the Cement Slurry Sample No
NUMBER
Density_Method STRING32 NA
The method used to determine the density of the cement slurry No
VARCHAR2(32)
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Filtrate_Volume double Volume
m3
The volume of filtrate measured in a filtration test No
NUMBER
Final_GLR double Gas_To_Liquid_Ratio
m3/m3
Final gas to liquid ratio in the foam job No
NUMBER
First_Comp_Strength double Strength
kPa
Compressive Strength as in First Test No
NUMBER
First_Comp_Strength_Time double Time
s
Time Duration of First Test for Compressive Strength No
NUMBER
Fluid_Yield double Volume
m3
Yield expressed as volume of slurry formed per sack of cement or clay No
NUMBER
Free_Water_Percentage double Percent
%
Water Percent from Free Water Test No
NUMBER
Free_Water_Temp double Temperature
degC
Temperature of the free water No
NUMBER
Free_Water_Volume double Volume
m3
Volume of the free water No
NUMBER
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Gas_Type STRING32 NA
The type of gas used in the Cement Slurry No
VARCHAR2(32)
Gas_Volume double Volume
m3
The volume of gas used in the Cement Slurry No
NUMBER
HTHP_Filtrate_Volume double Small_Volume
cm3
Volume of the filtrate in a filtration process under HTHP conditions, based on API recommendation after 30 minutes No
NUMBER
HTHP_Pressure double Pressure
kPa
Operating pressure of the high temperature-high pressure filter press. API specification is 500 psi. No
NUMBER
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Initial_GLR double Gas_To_Liquid_Ratio
m3/m3
Initial Gas Liquid Ratio for foam cementation No
NUMBER
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Mix_Water_Ratio double Volume_Per_Mass
m3/kg
The ratio of water to solid in the Cement Slurry mix. No
NUMBER
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Nominal_GLR double Gas_To_Liquid_Ratio
m3/m3
Gas Liquid Ratio (using constant density method) for foam cementation No
NUMBER
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Plastic_Viscosity double Dynamic_Viscosity
cP
The tangential shearing force (in excess of the yield point value) required to induce a unit rate of shear in the material from the sample that is being analyzed. It assumes that the material obeys the Bingham law of plastic flow. A newtonian fluid has a yield point value of zero. If a Fann viscometer is used then this could be quoted, in units of centipoise (cP), as the 600 rpm reading - 300 rpm reading. No
NUMBER
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Sample_Temperature double Temperature
degC
The temperature of the sample being tested. No
NUMBER
Second_Comp_Strength double Strength
kPa
Compressive Strength as in Second Test No
NUMBER
Second_Comp_Strength_Time double Time
s
Time Duration of Second Test for Compressive Strength No
NUMBER
Slurry_Batch_Id Cement_Slurry
The batch of Cement Slurry that the test was performed on Yes
NUMBER(38)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Thickening_Estimated_Time double Time
s
Estimated Time duration for Thickening No
NUMBER
Thickening_Test_Pressure double Pressure
kPa
Thickening Test Pressure No
NUMBER
Thickening_Test_Temp double Temperature
degC
Thickening Test Temperature No
NUMBER
Thickening_Time double Time
s
Thickening Time No
NUMBER
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)
Water_Source CODE NA
A textual description of the source of the water No
VARCHAR2(64)
Water_Volume_Per_Sack double Volume
m3
The water volume per sack used in the formulation of the cement slurry No
NUMBER
Yield_Stress double Shear_Stress
Pa
Resistance to initial flow; the stress required to start fluid movement. Specifically, shear stress at 0 shear rate for Bingham Plastic (BP) theological model, otherwise named Bingham yield value or yield point. No
NUMBER


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Cement_Slurry_Test Cement_Slurry_Test The test that produced the properties of the cement slurry Nullify No
Slurry_Batch Cement_Slurry The batch of Cement Slurry that the test was performed on Cascade Yes


[Seabed Objects] [Entities in Schema Seabed] [Index]