Ctrl_Panel_Oper_Pty_Set


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Ctrl_Panel_Oper_Pty_Set
Entity Type Table
Description The operating properties of a control panel
Submodel Artificial_Lift
Entity Scope Project
Primary Key Id
Natural Key Control_Panel_Id , Start_Date , Existence_Kind , Version
Generalizations Operating_Property_Set , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Control_Panel_Id Control_Panel
The control panel to which these operating properties relate Yes
NUMBER(38)
End_Date DATE NA
End date and time of the validity of these properties No
DATE
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Final_CT_Ratio double No_Unit
The final current transformer ratio identifies the changes (connections and / or turns of wire through the window) made to provide the proper current setting for the system measuring devices No
NUMBER
Fuse_Capacity_Current double Electric_Current
mA
Switchboard Fuse capacity No
NUMBER
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Initial_CT_Ratio double No_Unit
The initial ratio is current transformer ratio for a given connection, with 1 turn of wire through the window of the current transformer No
NUMBER
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Measuring_Activity_Id Generic_Wellsite_Activity
The activity that measured the Control Panel operating properties No
NUMBER(38)
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Overload_Current double Electric_Current
mA
Overload Setting Amperage for Switchboard No
NUMBER
Overload_Percent double Percent
%
Overload Setting Percentage for Switchboard No
NUMBER
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Start_Date DATE NA
Start date and time of the validity of these properties Yes
DATE
Underload_Current double Electric_Current
mA
Under-load Setting Amperage for Switchboard No
NUMBER
Underload_Percent double Percent
%
Under-load Setting Percentage for Switchboard No
NUMBER
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
VSD_Base_Frequency double Frequency
Hz
The base operating frequency setting for a VSD No
NUMBER
VSD_High_Frequency double Frequency
Hz
The high frequency limit for a VSD No
NUMBER
VSD_Low_Frequency double Frequency
Hz
The low frequency limit for a VSD No
NUMBER
VSD_Operating_Frequency double Frequency
Hz
The operating frequency setting for a VSD. No
NUMBER
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Measuring_Activity Generic_Wellsite_Activity The activity that measured the Control Panel operating properties Nullify No
Control_Panel Control_Panel The control panel to which these operating properties relate Cascade Yes


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2018 Schlumberger. All rights reserved.