Name | ESP_Oper_Pty_Set |
---|---|
Entity Type | Table |
Description | The operating properties of an ESP. When an ESP is placed in the borehole is ceases to be a collection of components and becomes more of a system. These are the properties of the system. |
Submodel | Artificial_Lift |
Entity Scope | Project |
Primary Key | Id |
Natural Key | ESP_Id , Start_Date , Existence_Kind , Version |
Generalizations | Operating_Property_Set , Entity , IT_Object , Tracked_Object |
Specializations |
Name | Value Domain | Property / Storage Unit | Description | Required / Default | Type |
---|---|---|---|---|---|
A_To_B_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase A to Phase B of the ESP system | No |
NUMBER |
A_To_Ground_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase A to ground of the ESP system | No |
NUMBER |
Application_HP | double | NA |
The horsepower of the motor system for a given application. This is usually calculated from the values of the application HP of the component motors. | No |
NUMBER |
B_To_C_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase B to Phase C of the ESP system | No |
NUMBER |
B_To_Ground_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase B to ground of the ESP system | No |
NUMBER |
C_To_A_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase C to Phase A of the ESP system | No |
NUMBER |
C_To_Ground_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase C to ground of the ESP system | No |
NUMBER |
Cable_A_To_B_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase A to Phase B of the ESP Cable | No |
NUMBER |
Cable_A_To_Ground_Resist | double | Electric_Resistance ohm |
The resistance reading from Phase A to ground of the ESP Cable | No |
NUMBER |
Cable_B_To_C_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase B to Phase C of the ESP Cable | No |
NUMBER |
Cable_B_To_Ground_Resist | double | Electric_Resistance ohm |
The resistance reading from Phase B to ground of the ESP Cable | No |
NUMBER |
Cable_C_To_A_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase C to Phase A of the ESP Cable | No |
NUMBER |
Cable_C_To_Ground_Resist | double | Electric_Resistance ohm |
The resistance reading from Phase C to ground of the ESP Cable | No |
NUMBER |
Calibration_Full_Scale_Ref | double | No_Unit |
The full scale reference value for the monitoring system installed in a well | No |
NUMBER |
Calibration_Zero_Ref | double | No_Unit |
The zero reference value for the monitoring system installed in a well | No |
NUMBER |
Current_Leakage | double | Electric_Current mA |
A measure of the current leakage from the ESP | No |
NUMBER |
Discharge_Pressure | double | Pressure kPa |
The pressure measured at the discharge point of the ESP. | No |
NUMBER |
Discharge_Temperature | double | Temperature degC |
The temperature measured at the discharge point of the ESP. | No |
NUMBER |
Discharge_Vibration | double | Gravity gn |
The vibration of the ESP system as measured at the outlet by a downhole sensor | No |
NUMBER |
Discharge_Vibration_X | double | Gravity gn |
The vibration of the ESP system as measured at the outlet by a downhole sensor in the X plane | No |
NUMBER |
Discharge_Vibration_Y | double | Gravity gn |
The vibration of the ESP system as measured at the outlet by a downhole sensor in the Y plane | No |
NUMBER |
Discharge_Vibration_Z | double | Gravity gn |
The vibration of the ESP system as measured at the outlet by a downhole sensor in the Z plane | No |
NUMBER |
ESP_Id | ESP |
|
The ESP system to which the operating properties belong | Yes |
NUMBER(38) |
End_Date | DATE | NA |
End date and time of the validity of these properties | No |
DATE |
Existence_Kind | REF_EXISTENCE_KIND | NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
Flowing_Downhole_Pressure | double | Pressure kPa |
Flowing downhole pressure reading. | No |
NUMBER |
GUID | STRING128 | NA |
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. | No |
VARCHAR2(128) |
Id | ID | No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
Insert_Date | DATE | NA |
Date the entity was created in the repository | No |
DATE |
Insert_User | STRING64 | NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
Intake_Pressure | double | Pressure kPa |
The pressure measured at the intake of the ESP. | No |
NUMBER |
Intake_Temperature | double | Temperature degC |
The temperature measured at the intake of the ESP. | No |
NUMBER |
Load_Voltage | double | Electric_Potential V |
The voltage of the system with the system running | No |
NUMBER |
Measuring_Activity_Id | Generic_Wellsite_Activity |
|
The activity that measured the ESP operating properties | No |
NUMBER(38) |
Motor_A_To_B_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase A to Phase B of the motor assembly | No |
NUMBER |
Motor_A_To_Ground_Resist | double | Electric_Resistance ohm |
The resistance reading from Phase A to ground of the motor assembly | No |
NUMBER |
Motor_B_To_C_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase B to Phase C of the motor assembly | No |
NUMBER |
Motor_B_To_Ground_Resist | double | Electric_Resistance ohm |
The resistance reading from Phase B to ground of the motor assembly | No |
NUMBER |
Motor_C_To_A_Resistance | double | Electric_Resistance ohm |
The resistance reading from Phase C to Phase A of the motor assembly | No |
NUMBER |
Motor_C_To_Ground_Resist | double | Electric_Resistance ohm |
The resistance reading from Phase C to ground of the motor assembly | No |
NUMBER |
Motor_Temperature | double | Temperature degC |
The temperature of the motor as measured by a downhole sensor | No |
NUMBER |
Motor_Vibration | double | Gravity gn |
The vibration of the ESP system as measured at the motor by a downhole sensor | No |
NUMBER |
Motor_Vibration_X | double | Gravity gn |
The vibration of the ESP system as measured at the motor by a downhole sensor in the X plane | No |
NUMBER |
Motor_Vibration_Y | double | Gravity gn |
The vibration of the ESP system as measured at the motor by a downhole sensor in the Y plane | No |
NUMBER |
Motor_Vibration_Z | double | Gravity gn |
The vibration of the ESP system as measured at the motor by a downhole sensor in the Z plane | No |
NUMBER |
Name | ENTITY_NAME | NA |
The name given to any object or data item, e.g. name of Well, name of Field, etc. | No |
VARCHAR2(255) |
No_Load_Voltage | double | Electric_Potential V |
The voltage of the system with the system not running | No |
NUMBER |
Original_Source | STRING64 | NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
Produced_By | STRING64 | NA |
The name of application role that created the entity, for data created programmatically. | No |
VARCHAR2(64) |
Pump_Up_Time | double | Time s |
The time taken for the fluid to reach the surface | No |
NUMBER |
Remarks | STRING2000 | NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
Rotational_Phasing_Desc | CODE | NA |
The description of the rotational phasing of the power for an ESP system. This can be "ABC" or "CBA" | No |
VARCHAR2(64) |
SDAT_Label | int | No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
Settled_Current | double | Electric_Current mA |
The settled system current with a constant pump load on the motor | No |
NUMBER |
Settling_Time | double | Time s |
The time take for the system to establish a settled state | No |
NUMBER |
Source | STRING64 | NA |
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
Start_Count | int | No_Unit |
The number of times this ESP has been "started" during this period | No |
NUMBER(10) |
Start_Current | double | Electric_Current mA |
The start current for the system. Indicates the load on the motor | No |
NUMBER |
Start_Date | DATE | NA |
Start date and time of the validity of these properties | Yes |
DATE |
Static_Downhole_Pressure | double | Pressure kPa |
Static downhole pressure reading | No |
NUMBER |
Update_Date | DATE | NA |
Date of the most-recent modification to the entity. | No |
DATE |
Update_User | STRING64 | NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
Version | STRING255 | NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
Y_Point_Voltage | double | Electric_Potential V |
The Voltage as measured at the Y-point on the bottom of the ESP Motor. This measurement is carried to the surface by downhole sensor telemetry. | No |
NUMBER |
From Entity | Link | Description | Implementation Technique | Required |
---|---|---|---|---|
ESP_Sensor_Oper_Pty_Set | ESP_Oper_Pty_Set | The identifier of the ESP operating property to which these sensor values apply. | Cascade | Yes |
Link | To Entity | Description | Implementation Technique | Required |
---|---|---|---|---|
Measuring_Activity | Generic_Wellsite_Activity | The activity that measured the ESP operating properties | Nullify | No |
ESP | ESP | The ESP system to which the operating properties belong | Cascade | Yes |