Facility_Operation_Test


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Facility_Operation_Test
Entity Type Table
Description A test performed on a facility for the purposes of ascertaining the operating properties of the facility. For example a pressure test of a BOP.
Submodel WS_Activity
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Wellsite_Activity , Activity , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Activity_Program_Id Activity_Program
Reference to the program during which the activity was performed. No
NUMBER(38)
Activity_State STRING64 NA
The current state, or status, of the activity. Activity state is a refinement of the lifecycle indicator Existence_Kind. For example, a drilling job whose Existence_Kind is "Actual" could have an activity state of "turning to the right", "suspended due to weather", or "tool makeup or breakdown". An activity whose Existence_Kind is "Required" could have State values like "under investigation", "proposed" and "AFE approved". Note: The valid list of activity states will vary from one kind of activity to another, so the values entered into this column are not validated via a lookup table. No
VARCHAR2(64)
Activity_Template_Id Activity_Template
The identifier of the activity template which activates or characterizes the Activity. No
NUMBER(38)
Duration double Time
s
The duration of the activity. For planned activities, this would be expected duration. No
NUMBER
End_Date DATE NA
The date and time at which the activity will end or did end. For planned activities, this would be expected end date. No
DATE
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
External_Reference STRING64 NA
A value that is used by an external organization to reference this activity. For example, if an external organization is hired to perform this activity, this column could be used to store the work order or purchase order number that organization uses to reference this activity. No
VARCHAR2(64)
Failed_Flag boolean NA
A flag to denote whether the facility passed or failed the test No
NUMBER(1)
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Internal_Reference STRING64 NA
A value that is used internally within the organization to reference this activity. No
VARCHAR2(64)
Lost_Volume double Volume
m3
The volume of fluid lost during the test No
NUMBER
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Pumped_Volume double Volume
m3
The volume of fluid pumped during the test No
NUMBER
Purpose STRING255 NA
A description of purpose of the activity or its stage No
VARCHAR2(255)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Start_Date DATE NA
The date and time at which the activity will start or did start. For planned activities, this would be expected start date. No
DATE
Test_Fluid_Id Generic_Wellsite_Fluid
The fluid used to test the facility Yes
NUMBER(38)
Test_Pressure double Pressure
kPa
The maximum pressure used during the test No
NUMBER
Test_Type R_Facility_Operation_Test
The type of operation test Yes
VARCHAR2(64)
Tested_Facility_Id Facility
The facility that is the subject of the test Yes
NUMBER(38)
Tested_Facility_Tbl Meta_Entity
Facility type Yes
VARCHAR2(30)
Time_Offset double Time
s
The time offset from the start of the program that this activity is scheduled to start at. This is normally used while planning a job. No
NUMBER
Total_Cost double No_Unit
The total cost of the activity expressed in the local currency. No
NUMBER
Transient_Period R_Transient_Period
A code or name that indicates whether the activity is executed daily, monthly, on demand, etc. No
VARCHAR2(64)
Triggering_Event_Id Event
The identifier of the event that triggered the start of this activity. Events can trigger activities. For example, an explosion event could trigger a firefighting activity. Note that this value should not conflict with, or be confused with, the value in Activity_Status.Triggering_Event. No
NUMBER(38)
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Referenced By

[Previous] [Next] [Top]
From EntityLinkDescriptionImplementation TechniqueRequired
Facility_Test_Detail Facility_Operation_Test The test to which these detail records belong. Cascade Yes


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Test_Type R_Facility_Operation_Test The type of operation test Restrict Yes
Tested_Facility Facility The facility that is the subject of the test Cascade Yes
Test_Fluid Generic_Wellsite_Fluid The fluid used to test the facility Restrict Yes
Activity_Template Activity_Template _ Restrict No
Activity_Program Activity_Program _ Restrict No
Triggering_Event Event _ Nullify No
Transient_Period R_Transient_Period _ Restrict No
Super_Activity Activity _ Assoc to One No
Fulfilled_Activity Activity _ Assoc to Many No


[Seabed Objects] [Entities in Schema Seabed] [Index]