Generic_Pump_Oper_Pty_Set


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Generic_Pump_Oper_Pty_Set
Entity Type Table
Description A collection of the "operating" properties of a generic pump. Operating properties are those properties whose values can change over time.
Submodel Facility
Entity Scope Project
Primary Key Id
Natural Key Pump_Id , Start_Date , Existence_Kind , Version
Generalizations Operating_Property_Set , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Differential_Pressure double Pressure
kPa
The fluid pressure differential across the pump No
NUMBER
Discharge_Pressure double Pressure
kPa
The pressure of the fluid at the discharge point of the pump No
NUMBER
End_Date DATE NA
End date and time of the validity of these properties No
DATE
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Flow_Rate double Flowrate
m3/h
The volume of the material that flowed through the pump during the specified time period. No
NUMBER
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Intake_Pressure double Pressure
kPa
The pressure as measured at the intake of the pump No
NUMBER
Measuring_Activity_Id Generic_Activity
The generic activity that was performed in order to determine the operating properties for the generic pump. No
NUMBER(38)
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Pressure_Ratio double Dimensionless
The absolute discharge pressure divided by the absolute suction pressure. No
NUMBER
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Pump_Efficiency double Percent
%
The ratio of the useful energy delivered by a dynamic system to the energy supplied to it. No
NUMBER
Pump_Id Generic_Pump
The identifier of the pump described by the set of operating properties. Yes
NUMBER(38)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Start_Date DATE NA
Start date and time of the validity of these properties Yes
DATE
Stroke_Rate double Frequency
Hz
The measured strokes per unit time of the pump. No
NUMBER
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Measuring_Activity Generic_Activity The generic activity that was performed in order to determine the operating properties for the generic pump. Nullify No
Pump Generic_Pump The identifier of the pump described by the set of operating properties. Cascade Yes


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2018 Schlumberger. All rights reserved.