Meter_Oper_Pty_Set


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Meter_Oper_Pty_Set
Entity Type Table
Description A collection of the "operating" properties of a meter. Operating properties are those properties whose values can change over time.
Submodel Facility
Entity Scope Project
Primary Key Id
Natural Key Meter_Id , Start_Date , Existence_Kind , Version
Generalizations Operating_Property_Set , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
End_Date DATE NA
End date and time of the validity of these properties No
DATE
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Fluid_Temperature double Temperature
degC
The temperature of the fluid that is being measured. No
NUMBER
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Meter_Correction_Factor double Dimensionless
A number that represents, for counter meters, an adjustment to the counter factor that results from meter calibration. In other words, it represents the ratio of what the meter actually measures divided by the counter factor (the volume the meter is supposed to measure per count). It is used in the following equation to calculate liquid volumes: Correction Factor * Counter Factor * Current Reading = Liquid Volume. For example, if the meter is supposed to measure 1 barrel per count; but it actually measures .98 barrels per count, the meter correction factor would be .98/1, or .98. No
NUMBER
Meter_Id Meter
The identifier of the meter described by the set of operating properties. Yes
NUMBER(38)
Meter_Line_Pressure double Pressure
kPa
The line pressure at the meter location. For orifice meters, it represents the pressure at the location of the meter tap that measures static pressure. No
NUMBER
Meter_Reading double No_Unit
The meter reading. No
NUMBER
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Orifice_Diff_Pressure double Pressure
kPa
The differential pressure across the orifice plate of the meter. (Only valid for orifice meters.) No
NUMBER
Orifice_Size double Cylinder_Diameter
mm
The diameter of the orifice opening. (Only valid for orifice meters.) No
NUMBER
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Start_Date DATE NA
Start date and time of the validity of these properties Yes
DATE
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Meter Meter The identifier of the meter described by the set of operating properties. Cascade Yes


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2018 Schlumberger. All rights reserved.