PVT_Curve_Data


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name PVT_Curve_Data
Entity Type Table
Description A collection of data values determined via a Pressure, Volume and Temperature test. The intersection of the data values can represent a point on a 2D graph, multidimensional graph, or cross-plot.
Submodel Fluid_Analysis
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Final_Pressure double Pressure
kPa
The final pressure when the data point was observed. No
NUMBER
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Initial_Pressure double Pressure
kPa
The initial pressure when the data point was observed. No
NUMBER
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
PVT_Curve_Data_Set_Id PVT_Curve_Data_Set
The identifier of the PVT Curve data set pertaining to this collection of PVT data Yes
NUMBER(38)
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Property_10_UOM R_Unit
The unit of measure in which the Property_10_Value value is specified. No
VARCHAR2(64)
Property_10_Value double No_Unit
The value of the 10th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_11_UOM R_Unit
The unit of measure in which the Property_11_Value value is specified. No
VARCHAR2(64)
Property_11_Value double No_Unit
The value of the 11th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_1_UOM R_Unit
The unit of measure in which the Property_1_Value value is specified. Yes
VARCHAR2(64)
Property_1_Value double No_Unit
The value of the 1st curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. Yes
NUMBER
Property_2_UOM R_Unit
The unit of measure in which the Property_2_Value value is specified. No
VARCHAR2(64)
Property_2_Value double No_Unit
The value of the 2nd curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_3_UOM R_Unit
The unit of measure in which the Property_3_Value value is specified. No
VARCHAR2(64)
Property_3_Value double No_Unit
The value of the 3rd curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_4_UOM R_Unit
The unit of measure in which the Property_4_Value value is specified. No
VARCHAR2(64)
Property_4_Value double No_Unit
The value of the 4th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_5_UOM R_Unit
The unit of measure in which the Property_5_Value value is specified. No
VARCHAR2(64)
Property_5_Value double No_Unit
The value of the 5th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_6_UOM R_Unit
The unit of measure in which the Property_6_Value value is specified. No
VARCHAR2(64)
Property_6_Value double No_Unit
The value of the 6th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_7_UOM R_Unit
The unit of measure in which the Property_7_Value value is specified. No
VARCHAR2(64)
Property_7_Value double No_Unit
The value of the 7th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_8_UOM R_Unit
The unit of measure in which the Property_8_Value value is specified. No
VARCHAR2(64)
Property_8_Value double No_Unit
The value of the 8th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Property_9_UOM R_Unit
The unit of measure in which the Property_9_Value value is specified. No
VARCHAR2(64)
Property_9_Value double No_Unit
The value of the 9th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. No
NUMBER
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Sequence_Number int No_Unit
A number to define the position of this point within the data set. No
NUMBER(10)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Temperature double Temperature
degC
The temperature when the data point was observed. No
NUMBER
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
PVT_Curve_Data_Set PVT_Curve_Data_Set The identifier of the PVT Curve data set pertaining to this collection of PVT data Cascade Yes
Property_10_UOM R_Unit The unit of measure in which the Property_10_Value value is specified. Restrict No
Property_9_UOM R_Unit The unit of measure in which the Property_9_Value value is specified. Restrict No
Property_8_UOM R_Unit The unit of measure in which the Property_8_Value value is specified. Restrict No
Property_11_UOM R_Unit The unit of measure in which the Property_11_Value value is specified. Restrict No
Property_7_UOM R_Unit The unit of measure in which the Property_7_Value value is specified. Restrict No
Property_2_UOM R_Unit The unit of measure in which the Property_2_Value value is specified. Restrict No
Property_3_UOM R_Unit The unit of measure in which the Property_3_Value value is specified. Restrict No
Property_4_UOM R_Unit The unit of measure in which the Property_4_Value value is specified. Restrict No
Property_5_UOM R_Unit The unit of measure in which the Property_5_Value value is specified. Restrict No
Property_6_UOM R_Unit The unit of measure in which the Property_6_Value value is specified. Restrict No
Property_1_UOM R_Unit The unit of measure in which the Property_1_Value value is specified. Restrict Yes


[Seabed Objects] [Entities in Schema Seabed] [Index]