Name | PVT_Curve_Data |
---|---|
Entity Type | Table |
Description | A collection of data values determined via a Pressure, Volume and Temperature test. The intersection of the data values can represent a point on a 2D graph, multidimensional graph, or cross-plot. |
Submodel | Fluid_Analysis |
Entity Scope | Project |
Primary Key | Id |
Natural Key | |
Generalizations | Entity , IT_Object , Tracked_Object |
Specializations |
Name | Value Domain | Property / Storage Unit | Description | Required / Default | Type |
---|---|---|---|---|---|
Existence_Kind | REF_EXISTENCE_KIND | NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
Final_Pressure | double | Pressure kPa |
The final pressure when the data point was observed. | No |
NUMBER |
GUID | STRING128 | NA |
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. | No |
VARCHAR2(128) |
Id | ID | No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
Initial_Pressure | double | Pressure kPa |
The initial pressure when the data point was observed. | No |
NUMBER |
Insert_Date | DATE | NA |
Date the entity was created in the repository | No |
DATE |
Insert_User | STRING64 | NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
Name | ENTITY_NAME | NA |
The name given to any object or data item, e.g. name of Well, name of Field, etc. | No |
VARCHAR2(255) |
Original_Source | STRING64 | NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
PVT_Curve_Data_Set_Id | PVT_Curve_Data_Set |
|
The identifier of the PVT Curve data set pertaining to this collection of PVT data | Yes |
NUMBER(38) |
Produced_By | STRING64 | NA |
The name of application role that created the entity, for data created programmatically. | No |
VARCHAR2(64) |
Property_10_UOM | R_Unit |
|
The unit of measure in which the Property_10_Value value is specified. | No |
VARCHAR2(64) |
Property_10_Value | double | No_Unit |
The value of the 10th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_11_UOM | R_Unit |
|
The unit of measure in which the Property_11_Value value is specified. | No |
VARCHAR2(64) |
Property_11_Value | double | No_Unit |
The value of the 11th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_1_UOM | R_Unit |
|
The unit of measure in which the Property_1_Value value is specified. | Yes |
VARCHAR2(64) |
Property_1_Value | double | No_Unit |
The value of the 1st curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | Yes |
NUMBER |
Property_2_UOM | R_Unit |
|
The unit of measure in which the Property_2_Value value is specified. | No |
VARCHAR2(64) |
Property_2_Value | double | No_Unit |
The value of the 2nd curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_3_UOM | R_Unit |
|
The unit of measure in which the Property_3_Value value is specified. | No |
VARCHAR2(64) |
Property_3_Value | double | No_Unit |
The value of the 3rd curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_4_UOM | R_Unit |
|
The unit of measure in which the Property_4_Value value is specified. | No |
VARCHAR2(64) |
Property_4_Value | double | No_Unit |
The value of the 4th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_5_UOM | R_Unit |
|
The unit of measure in which the Property_5_Value value is specified. | No |
VARCHAR2(64) |
Property_5_Value | double | No_Unit |
The value of the 5th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_6_UOM | R_Unit |
|
The unit of measure in which the Property_6_Value value is specified. | No |
VARCHAR2(64) |
Property_6_Value | double | No_Unit |
The value of the 6th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_7_UOM | R_Unit |
|
The unit of measure in which the Property_7_Value value is specified. | No |
VARCHAR2(64) |
Property_7_Value | double | No_Unit |
The value of the 7th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_8_UOM | R_Unit |
|
The unit of measure in which the Property_8_Value value is specified. | No |
VARCHAR2(64) |
Property_8_Value | double | No_Unit |
The value of the 8th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Property_9_UOM | R_Unit |
|
The unit of measure in which the Property_9_Value value is specified. | No |
VARCHAR2(64) |
Property_9_Value | double | No_Unit |
The value of the 9th curve data point property. The name of the property associated with this value can be determined via the R_PVT_Curve_Property_Set table. | No |
NUMBER |
Remarks | STRING2000 | NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
SDAT_Label | int | No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
Sequence_Number | int | No_Unit |
A number to define the position of this point within the data set. | No |
NUMBER(10) |
Source | STRING64 | NA |
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
Temperature | double | Temperature degC |
The temperature when the data point was observed. | No |
NUMBER |
Update_Date | DATE | NA |
Date of the most-recent modification to the entity. | No |
DATE |
Update_User | STRING64 | NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
Version | STRING255 | NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
Link | To Entity | Description | Implementation Technique | Required |
---|---|---|---|---|
PVT_Curve_Data_Set | PVT_Curve_Data_Set | The identifier of the PVT Curve data set pertaining to this collection of PVT data | Cascade | Yes |
Property_10_UOM | R_Unit | The unit of measure in which the Property_10_Value value is specified. | Restrict | No |
Property_9_UOM | R_Unit | The unit of measure in which the Property_9_Value value is specified. | Restrict | No |
Property_8_UOM | R_Unit | The unit of measure in which the Property_8_Value value is specified. | Restrict | No |
Property_11_UOM | R_Unit | The unit of measure in which the Property_11_Value value is specified. | Restrict | No |
Property_7_UOM | R_Unit | The unit of measure in which the Property_7_Value value is specified. | Restrict | No |
Property_2_UOM | R_Unit | The unit of measure in which the Property_2_Value value is specified. | Restrict | No |
Property_3_UOM | R_Unit | The unit of measure in which the Property_3_Value value is specified. | Restrict | No |
Property_4_UOM | R_Unit | The unit of measure in which the Property_4_Value value is specified. | Restrict | No |
Property_5_UOM | R_Unit | The unit of measure in which the Property_5_Value value is specified. | Restrict | No |
Property_6_UOM | R_Unit | The unit of measure in which the Property_6_Value value is specified. | Restrict | No |
Property_1_UOM | R_Unit | The unit of measure in which the Property_1_Value value is specified. | Restrict | Yes |