Acquisition_Device


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Acquisition_Device
Entity Type Table
Description A measurement controlling device.
Submodel Facility
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Tracked_Facility , Facility , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Acquisition_Device_Cat R_Acquisition_Device_Cat
The type of acquisition device No
NUMBER(38)
Acquisition_Device_Type R_Acquisition_Device
The type of acquisition device. For example, OPC, DTS, etc. No
VARCHAR2(64)
Address_Id Address
The address of the Tracked Facility No
NUMBER(38)
Catalog_Cost double No_Unit
The catalog cost of the piece of equipment or facility expressed in the currency denoted by the attribute Catalog_Currency No
NUMBER
Catalog_Currency R_Currency
The currency in which the catalog cost is expressed. No
VARCHAR2(64)
Catalog_Number STRING64 NA
A catalog or part number for a facility. No
VARCHAR2(64)
Configuration_File_Name STRING128 NA
The name of the file used to configure the densitometer. No
VARCHAR2(128)
Depth_Description STRING64 NA
Optional depth if the device is in the borehole. No
VARCHAR2(64)
Device_Position STRING64 NA
Description of the device position in the well for the user, e.g. downhole. No
VARCHAR2(64)
Device_RTU_Address STRING64 NA
Address of the device (e.g. @modbus for the PAC) No
VARCHAR2(64)
End_Date DATE NA
Date that the device is decommissioned. No
DATE
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Facility_Equipment_Flag CODE NA
A flag to denote whether a given facility should be treated as a facility (F), a piece of equipment (E) or both (B). A facility labeled as F represents a role (e.g. ESP) played by physical piece(s) of equipment and would not have attributes like serial number, manufacturer etc. It can be related to the physical pieces(s) of equipment using Facility_Composition. The individual physical pieces can be replaced if they need to be, without changing the facility. A Facility labeled as E represents a physical piece of equipment (e.g. Drill Pipe) which is normally used in the context of an activity and would not be permanently installed. A facility labeled as B represents both a physical piece of equipment as well as the role played by it. If this kind of Facility is connected in the network and stops working and needs to be replaced, then all connections to this Facility are expired and new connections are made to the replacement facility. No
VARCHAR2(64)
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Inventory_Id STRING64 NA
The formal identification for a piece of equipment, a serial number or inventory ID No
VARCHAR2(64)
Loaded_Date DATE NA
The date that the software configuration was loaded into the DAFC No
DATE
Manufacture_Date DATE NA
Date of manufacturing the facility. No
DATE
Manufacturer STRING64 NA
Name of the business associate who manufactured the item. No
VARCHAR2(64)
Material_Type STRING64 NA
The primary material type of facility. No
VARCHAR2(64)
Model_Name STRING64 NA
Name of a model or version of some entity; for equipment, it may coincide with the trade name. No
VARCHAR2(64)
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Operating_Mode STRING64 NA
The operating mode of the device. For example Oil Mode, Gas Mode or Dual Mode. Used for the configuration of DAFCs No
VARCHAR2(64)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Serial_Number STRING64 NA
The serial number placed on a piece of equipment. No
VARCHAR2(64)
Size_Description STRING64 NA
A textual description of the size of the piece of equipment. For example 8 1/2 inch. No
VARCHAR2(64)
Software_Version STRING64 NA
The version of software loaded into the acquisition device No
VARCHAR2(64)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Start_Date DATE NA
Date that the device is put in operation. No
DATE
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Vendor_Id Company
The company from which the facility was purchased. No
NUMBER(38)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Referenced By

[Previous] [Next] [Top]
From EntityLinkDescriptionImplementation TechniqueRequired
Measurement_Tag Acquisition_Device The control device for the measurement tag where the value of the measurement tag is recorded or set. Cascade No


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Acquisition_Device_Cat R_Acquisition_Device_Cat The type of acquisition device Restrict No
Acquisition_Device_Type R_Acquisition_Device The type of acquisition device. For example, OPC, DTS, etc. Restrict No
Catalog_Currency R_Currency _ Restrict No
Address Address _ Nullify No
Vendor Company _ Nullify No


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2018 Schlumberger. All rights reserved.