ESP_Cable


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name ESP_Cable
Entity Type Table
Description Entity describing data for both ESP Main Power Cable and ESP Motor Flat Cable.
Submodel Artificial_Lift
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Tracked_Facility , Facility , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Address_Id Address
The address of the Tracked Facility No
NUMBER(38)
Armor_Type CODE NA
Armor metal protection of ESP cables, for example "Double Galvanized" No
VARCHAR2(64)
Cable_Profile CODE NA
The profile of the cable. For example is it round or flat. No
VARCHAR2(64)
Cable_Type CODE NA
Type of ESP cable, for example "EER", "ELTB" Yes
VARCHAR2(64)
Catalog_Cost double No_Unit
The catalog cost of the piece of equipment or facility expressed in the currency denoted by the attribute Catalog_Currency No
NUMBER
Catalog_Currency R_Currency
The currency in which the catalog cost is expressed. No
VARCHAR2(64)
Catalog_Number STRING64 NA
A catalog or part number for a facility. No
VARCHAR2(64)
Conductor_Size double No_Unit
The size of the conductor in the cable. No
NUMBER
Conductor_Size_Unit CODE NA
The unit for the size of the conductor. For example AWG for American Wire Gauge. No
VARCHAR2(64)
ESP_Cable_Cat R_ESP_Cable_Cat
Reference to the catalog entry for this device No
NUMBER(38)
Engineering_Code STRING128 NA
A code containing concatenated attributes of equipment. The structure will vary with each equipment type. No
VARCHAR2(128)
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Facility_Equipment_Flag CODE NA
A flag to denote whether a given facility should be treated as a facility (F), a piece of equipment (E) or both (B). A facility labeled as F represents a role (e.g. ESP) played by physical piece(s) of equipment and would not have attributes like serial number, manufacturer etc. It can be related to the physical pieces(s) of equipment using Facility_Composition. The individual physical pieces can be replaced if they need to be, without changing the facility. A Facility labeled as E represents a physical piece of equipment (e.g. Drill Pipe) which is normally used in the context of an activity and would not be permanently installed. A facility labeled as B represents both a physical piece of equipment as well as the role played by it. If this kind of Facility is connected in the network and stops working and needs to be replaced, then all connections to this Facility are expired and new connections are made to the replacement facility. No
VARCHAR2(64)
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Insulation_Description CODE NA
Short description of Cable Insulation No
VARCHAR2(64)
Inventory_Id STRING64 NA
The formal identification for a piece of equipment, a serial number or inventory ID No
VARCHAR2(64)
Length double Length
m
Length of ESP Cable No
NUMBER
Manufacture_Date DATE NA
Date of manufacturing the facility. No
DATE
Manufacturer STRING64 NA
Name of the business associate who manufactured the item. No
VARCHAR2(64)
Material_Type STRING64 NA
The primary material type of facility. No
VARCHAR2(64)
Model_Name STRING64 NA
Name of a model or version of some entity; for equipment, it may coincide with the trade name. No
VARCHAR2(64)
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Pigtail_Description CODE NA
Short Description of Pigtail No
VARCHAR2(64)
Pothead_Type CODE NA
The type of connector between the motor and the power cable/motor lead. No
VARCHAR2(64)
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Rated_Voltage double Electric_Potential
V
The maximum voltage that this cable can safely hold No
NUMBER
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Serial_Number STRING64 NA
The serial number placed on a piece of equipment. No
VARCHAR2(64)
Series_Name CODE NA
The series number of power cable or motor lead. No
VARCHAR2(64)
Size_Description STRING64 NA
A textual description of the size of the piece of equipment. For example 8 1/2 inch. No
VARCHAR2(64)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Splice_Count int No_Unit
Number of Cable Splices No
NUMBER(10)
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Vendor_Id Company
The company from which the facility was purchased. No
NUMBER(38)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
ESP_Cable_Cat R_ESP_Cable_Cat Reference to the catalog entry for this device Restrict No
Catalog_Currency R_Currency _ Restrict No
Address Address _ Nullify No
Vendor Company _ Nullify No


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2018 Schlumberger. All rights reserved.