Name | Facility_Connection |
---|---|
Entity Type | Table |
Description | An association denoting that one facility is connected to another. The entire list of facility connections is what will comprise the physical network. |
Submodel | Facility |
Entity Scope | Project |
Primary Key | Id |
Natural Key | |
Generalizations | Transient_Association , IT_Object , Tracked_Object |
Specializations |
Name | Value Domain | Property / Storage Unit | Description | Required / Default | Type |
---|---|---|---|---|---|
Connection_Type | R_Facility_Connection |
|
A link to show the connection type of the Facility_Connection. For example Welded etc. | No |
VARCHAR2(64) |
End_Date | DATE | NA |
End time of the association | No |
DATE |
Existence_Kind | REF_EXISTENCE_KIND | NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
From_Connector_Id | Facility_Connector |
|
Reference to the connector as the part that has been connected from. | No |
NUMBER(38) |
From_Facility_Id | Facility |
|
Reference to the Facility as the part that has been connected from. | Yes |
NUMBER(38) |
From_Facility_Tbl | Meta_Entity |
|
Facility type | Yes |
VARCHAR2(30) |
From_Mounting_Location | MOUNTING_LOCATION_TYPE | NA |
Relative position of the From_Connector in a facility connection. The options are: Top, Bottom, Inside, Outside. Illustration: If A is the From_Connector and B is the To_Connector, then the From_Mounting_Location will be specified as (1) Top, when A is on Top of B, (2) Bottom, when A is on Bottom of B, (3) Inside, when A is inside B, (4) Outside, when A is outside B. It is important to note that, in this example, the From_Mounting_Location always refers to where A is located because A is the From_Connector. | No |
VARCHAR2(64) |
From_Offset | double | Length m |
The distance from the mid-point of the "From" equipment to the readout port or Bottom end (make up line) of the "To" equipment in a From_To connection. | No |
NUMBER |
GUID | STRING128 | NA |
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. | No |
VARCHAR2(128) |
Id | ID | No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
Insert_Date | DATE | NA |
Date the entity was created in the repository | No |
DATE |
Insert_User | STRING64 | NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
Produced_By | STRING64 | NA |
The name of application role that created the entity, for data created programmatically. | No |
VARCHAR2(64) |
SDAT_Label | int | No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
Start_Date | DATE | NA |
Start time of the association. | No |
DATE |
To_Connector_Id | Facility_Connector |
|
Reference to the connector as the part that has been connected to. | No |
NUMBER(38) |
To_Facility_Id | Facility |
|
Reference to the Facility as the part that has been connected to. | Yes |
NUMBER(38) |
To_Facility_Tbl | Meta_Entity |
|
Facility type | Yes |
VARCHAR2(30) |
Update_Date | DATE | NA |
Date of the most-recent modification to the entity. | No |
DATE |
Update_User | STRING64 | NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
Version | STRING255 | NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
From Entity | Link | Description | Implementation Technique | Required |
---|---|---|---|---|
Fac_Connection_Material | Facility_Connection | The identifier of the facility connection over which the specified material type could flow at the specified point in time. | Cascade | Yes |
Fac_Network_Connection | Facility_Connection | The facility connection that represents a part of the facility network. | Restrict | Yes |
Link | To Entity | Description | Implementation Technique | Required |
---|---|---|---|---|
To_Facility | Facility | Reference to the Facility as the part that has been connected to. | Cascade | Yes |
To_Connector | Facility_Connector | Reference to the connector as the part that has been connected to. | Cascade | No |
From_Connector | Facility_Connector | Reference to the connector as the part that has been connected from. | Cascade | No |
Connection_Type | R_Facility_Connection | A link to show the connection type of the Facility_Connection. For example Welded etc. | Restrict | No |
From_Facility | Facility | Reference to the Facility as the part that has been connected from. | Cascade | Yes |