Name | Facility_Connector |
---|---|
Entity Type | Table |
Description | A device or mechanism used to connect one facility to another. |
Submodel | Facility |
Entity Scope | Project |
Primary Key | Id |
Natural Key | |
Generalizations | Entity , IT_Object , Tracked_Object |
Specializations |
Name | Value Domain | Property / Storage Unit | Description | Required / Default | Type |
---|---|---|---|---|---|
Attachment_Pattern | STRING64 | NA |
The attachment pattern for the tubular accessory | No |
VARCHAR2(64) |
Compatible_Connection | CODE | NA |
A connector of a different type that will successfully mate with this connector | No |
VARCHAR2(64) |
Connector_Type | STRING64 | NA |
Type of connector used at a port (e.g., threaded, flanged) | No |
VARCHAR2(64) |
Critical_Cross_Section | double | Area m2 |
The critical cross section of a connector. Used for calculating bending stiffness ratio. | No |
NUMBER |
Drift_Diameter | double | Cylinder_Diameter mm |
The largest diameter object that can be successfully passed through the connector | No |
NUMBER |
Existence_Kind | REF_EXISTENCE_KIND | NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
Facility_Id | Facility |
|
Reference to the facility for which the connector has been defined. | Yes |
NUMBER(38) |
Facility_Tbl | Meta_Entity |
|
Facility type | Yes |
VARCHAR2(30) |
GUID | STRING128 | NA |
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. | No |
VARCHAR2(128) |
Gender | STRING1 | NA |
Gender of connector for example (B)ox vs. (P)in, (M)ale vs. (F)emale | No |
VARCHAR2(1) |
Hydrostatic_Test_Pressure | double | Pressure kPa |
The hydrostatic pressure rating of this connector | No |
NUMBER |
Id | ID | No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
Insert_Date | DATE | NA |
Date the entity was created in the repository | No |
DATE |
Insert_User | STRING64 | NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
Inside_Diameter | double | Cylinder_Diameter mm |
Actual Inside diameter of a connector (e.g., tool joint or flange). In the absence of the actual value the catalog value should be used. | No |
NUMBER |
Length | double | Length m |
Length of the connector | No |
NUMBER |
Linear_Weight | double | Mass_Per_Length kg/m |
Weight of a connector such as a tool joint per unit length | No |
NUMBER |
Material_Grade | CODE | NA |
The grade of the material used in the construction of this connector | No |
VARCHAR2(64) |
Max_Make_Up_Torque | double | High_Torque kN.m |
The torque above which you have over-torqued (damaged the threads). | No |
NUMBER |
Min_Make_Up_Torque | double | High_Torque kN.m |
The minimum torque required to make up the joint to meet the leak resistance spec. | No |
NUMBER |
Name | ENTITY_NAME | NA |
The name given to any object or data item, e.g. name of Well, name of Field, etc. | No |
VARCHAR2(255) |
Original_Source | STRING64 | NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
Outside_Diameter | double | Cylinder_Diameter mm |
Actual Outside diameter of a connector (e.g., tool joint or flange). In the absence of the actual value the catalog value should be used. | No |
NUMBER |
Produced_By | STRING64 | NA |
The name of application role that created the entity, for data created programmatically. | No |
VARCHAR2(64) |
Remarks | STRING2000 | NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
SDAT_Label | int | No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
Source | STRING64 | NA |
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
Standardization_Name | CODE | NA |
The standard body that holds the standard for this connector | No |
VARCHAR2(64) |
Stress_Relief_Flag | boolean | NA |
A flag to indicate whether or not a Stress Relief groove was provided. A Stress Relief groove is a groove at the shoulder of the pin to relieve excessive connection stress, increase connection flexibility, and reduce fatigue. | No |
NUMBER(1) |
Tensile_Strength | double | Strength kPa |
The Tensile strength of this connector | No |
NUMBER |
Thread_Category | CODE | NA |
A further sub-classification of the thread type E.g. Long Thread, Short Thread | No |
VARCHAR2(64) |
Thread_Inside_Diameter | double | Cylinder_Diameter mm |
Actual inside diameter of the first threaded connection. | No |
NUMBER |
Thread_Outside_Diameter | double | Cylinder_Diameter mm |
Actual outside diameter of the first threaded connection. Often called size, e.g., 2 1/4 | No |
NUMBER |
Thread_Type | R_Thread |
|
The thread type of the facility connector | No |
VARCHAR2(64) |
Torsional_Strength | double | Strength kPa |
The TORSIONAL strength of this connector | No |
NUMBER |
Update_Date | DATE | NA |
Date of the most-recent modification to the entity. | No |
DATE |
Update_User | STRING64 | NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
Upset_Type | CODE | NA |
A description of whether the upset (increase in thickness) of the pipe at the tool joint is External, Internal or both | No |
VARCHAR2(64) |
Version | STRING255 | NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
Weight | double | Force N |
The weight of the connector | No |
NUMBER |
From Entity | Link | Description | Implementation Technique | Required |
---|---|---|---|---|
Connector_Condition | Connector | The connector with which the condition record is associated | Cascade | Yes |
Facility_Connection | To_Connector | Reference to the connector as the part that has been connected to. | Cascade | No |
Facility_Connection | From_Connector | Reference to the connector as the part that has been connected from. | Cascade | No |
Link | To Entity | Description | Implementation Technique | Required |
---|---|---|---|---|
Facility | Facility | Reference to the facility for which the connector has been defined. | Cascade | Yes |
Thread_Type | R_Thread | The thread type of the facility connector | Restrict | No |