Facility_Connector


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Facility_Connector
Entity Type Table
Description A device or mechanism used to connect one facility to another.
Submodel Facility
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Attachment_Pattern STRING64 NA
The attachment pattern for the tubular accessory No
VARCHAR2(64)
Compatible_Connection CODE NA
A connector of a different type that will successfully mate with this connector No
VARCHAR2(64)
Connector_Type STRING64 NA
Type of connector used at a port (e.g., threaded, flanged) No
VARCHAR2(64)
Critical_Cross_Section double Area
m2
The critical cross section of a connector. Used for calculating bending stiffness ratio. No
NUMBER
Drift_Diameter double Cylinder_Diameter
mm
The largest diameter object that can be successfully passed through the connector No
NUMBER
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Facility_Id Facility
Reference to the facility for which the connector has been defined. Yes
NUMBER(38)
Facility_Tbl Meta_Entity
Facility type Yes
VARCHAR2(30)
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
Gender STRING1 NA
Gender of connector for example (B)ox vs. (P)in, (M)ale vs. (F)emale No
VARCHAR2(1)
Hydrostatic_Test_Pressure double Pressure
kPa
The hydrostatic pressure rating of this connector No
NUMBER
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Inside_Diameter double Cylinder_Diameter
mm
Actual Inside diameter of a connector (e.g., tool joint or flange). In the absence of the actual value the catalog value should be used. No
NUMBER
Length double Length
m
Length of the connector No
NUMBER
Linear_Weight double Mass_Per_Length
kg/m
Weight of a connector such as a tool joint per unit length No
NUMBER
Material_Grade CODE NA
The grade of the material used in the construction of this connector No
VARCHAR2(64)
Max_Make_Up_Torque double High_Torque
kN.m
The torque above which you have over-torqued (damaged the threads). No
NUMBER
Min_Make_Up_Torque double High_Torque
kN.m
The minimum torque required to make up the joint to meet the leak resistance spec. No
NUMBER
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Outside_Diameter double Cylinder_Diameter
mm
Actual Outside diameter of a connector (e.g., tool joint or flange). In the absence of the actual value the catalog value should be used. No
NUMBER
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Standardization_Name CODE NA
The standard body that holds the standard for this connector No
VARCHAR2(64)
Stress_Relief_Flag boolean NA
A flag to indicate whether or not a Stress Relief groove was provided. A Stress Relief groove is a groove at the shoulder of the pin to relieve excessive connection stress, increase connection flexibility, and reduce fatigue. No
NUMBER(1)
Tensile_Strength double Strength
kPa
The Tensile strength of this connector No
NUMBER
Thread_Category CODE NA
A further sub-classification of the thread type E.g. Long Thread, Short Thread No
VARCHAR2(64)
Thread_Inside_Diameter double Cylinder_Diameter
mm
Actual inside diameter of the first threaded connection. No
NUMBER
Thread_Outside_Diameter double Cylinder_Diameter
mm
Actual outside diameter of the first threaded connection. Often called size, e.g., 2 1/4 No
NUMBER
Thread_Type R_Thread
The thread type of the facility connector No
VARCHAR2(64)
Torsional_Strength double Strength
kPa
The TORSIONAL strength of this connector No
NUMBER
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Upset_Type CODE NA
A description of whether the upset (increase in thickness) of the pipe at the tool joint is External, Internal or both No
VARCHAR2(64)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)
Weight double Force
N
The weight of the connector No
NUMBER


Referenced By

[Previous] [Next] [Top]
From EntityLinkDescriptionImplementation TechniqueRequired
Connector_Condition Connector The connector with which the condition record is associated Cascade Yes
Facility_Connection To_Connector Reference to the connector as the part that has been connected to. Cascade No
Facility_Connection From_Connector Reference to the connector as the part that has been connected from. Cascade No


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Facility Facility Reference to the facility for which the connector has been defined. Cascade Yes
Thread_Type R_Thread The thread type of the facility connector Restrict No


[Seabed Objects] [Entities in Schema Seabed] [Index]