Name | Production_Packer |
---|---|
Entity Type | Table |
Description | A piece of downhole equipment, consisting of a sealing device, a holding or setting device, and an inside passage for fluids, used to block the flow of fluids through the annular space between the tubing and the wall of the wellbore by sealing off the space between them. |
Submodel | Tubular |
Entity Scope | Project |
Primary Key | Id |
Natural Key | |
Generalizations | Tubular , Tracked_Facility , Facility , Entity , IT_Object , Tracked_Object |
Specializations |
Name | Value Domain | Property / Storage Unit | Description | Required / Default | Type |
---|---|---|---|---|---|
Absolute_Roughness | double | Length m |
The absolute roughness of the inside wall of the tubular | No |
NUMBER |
Address_Id | Address |
|
The address of the Tracked Facility | No |
NUMBER(38) |
Axial_Stiffness | double | Spring_Stiffness N/m |
A measure of the inflexibility of a tubular in an axial plane | No |
NUMBER |
Bend_Stiffness | double | Spring_Stiffness N/m |
A measure of the inflexibility of a tubular in a longitudinal plane | No |
NUMBER |
Burst_Pressure | double | Pressure kPa |
Burst Pressure of the tubular | No |
NUMBER |
Catalog_Cost | double | No_Unit |
The catalog cost of the piece of equipment or facility expressed in the currency denoted by the attribute Catalog_Currency | No |
NUMBER |
Catalog_Currency | R_Currency |
|
The currency in which the catalog cost is expressed. | No |
VARCHAR2(64) |
Catalog_Number | STRING64 | NA |
A catalog or part number for a facility. | No |
VARCHAR2(64) |
Coating_Desc | STRING64 | NA |
A description of the coating applied to the tubular | No |
VARCHAR2(64) |
Collapse_Pressure | double | Pressure kPa |
Collapse pressure | No |
NUMBER |
Compressive_Strength | double | Pressure kPa |
Compressive Strength of tubular | No |
NUMBER |
Displacement_Volume | double | Volume_Per_Length m3/m |
The cross-sectional area of steel (or other material if the tubular is not made of steel) in the tubular expressed in units of volume per unit length. | No |
NUMBER |
Drift_Diameter | double | Cylinder_Diameter mm |
Largest diameter of a perfect cylinder that can fit into the pipe. Because a pipe is slightly oval the drift diameter is always smaller than the quoted inner diameter. The drift diameter is used to know if a given pipe will run into a pipe. | No |
NUMBER |
Elastomer_Type | CODE | NA |
Type of elastomer. Elastomer is an elastic material made of synthetic rubber or plastic; often the main component of the packing material in blowout preventers and downhole packers. | No |
VARCHAR2(64) |
Element_Center_Depth | double | Length m |
Distance from the hanger top to the center of the element. | No |
NUMBER |
Existence_Kind | REF_EXISTENCE_KIND | NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
Facility_Equipment_Flag | CODE | NA |
A flag to denote whether a given facility should be treated as a facility (F), a piece of equipment (E) or both (B). A facility labeled as F represents a role (e.g. ESP) played by physical piece(s) of equipment and would not have attributes like serial number, manufacturer etc. It can be related to the physical pieces(s) of equipment using Facility_Composition. The individual physical pieces can be replaced if they need to be, without changing the facility. A Facility labeled as E represents a physical piece of equipment (e.g. Drill Pipe) which is normally used in the context of an activity and would not be permanently installed. A facility labeled as B represents both a physical piece of equipment as well as the role played by it. If this kind of Facility is connected in the network and stops working and needs to be replaced, then all connections to this Facility are expired and new connections are made to the replacement facility. | No |
VARCHAR2(64) |
Fatigue_Endurance_Limit | double | Stress kPa |
The maximum stress below which the tubular could presumably endure an infinite number of cycles. | No |
NUMBER |
Fishneck_Inside_Diameter | double | Cylinder_Diameter mm |
The inside diameter of the fishneck. | No |
NUMBER |
Fishneck_Length | double | Length m |
Fishing neck length. This is defined as being the distance from the seal face to the location of any section change. | No |
NUMBER |
Fishneck_Outside_Diameter | double | Cylinder_Diameter mm |
The inside diameter of the fishneck. | No |
NUMBER |
GUID | STRING128 | NA |
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. | No |
VARCHAR2(128) |
Heavyweight_Flag | boolean | NA |
A flag to denote whether or not the tubular is classified as a "Heavyweight" tubular or not | No |
NUMBER(1) |
Hydraulic_Diameter | double | Cylinder_Diameter mm |
The equivalent hydraulic diameter of the tubular. | No |
NUMBER |
Hydrostatic_Test_Pressure | double | Pressure kPa |
The nominal test pressure that a tubular can safely hold | No |
NUMBER |
Id | ID | No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
Insert_Date | DATE | NA |
Date the entity was created in the repository | No |
DATE |
Insert_User | STRING64 | NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
Inside_Diameter | double | Cylinder_Diameter mm |
Actual Inside diameter of an entity, such as an item of drill string equipment. In the absence of the actual value the catalog value should be used | No |
NUMBER |
Inventory_Id | STRING64 | NA |
The formal identification for a piece of equipment, a serial number or inventory ID | No |
VARCHAR2(64) |
Joint_Count | int | No_Unit |
The number of joints of tubular goods. | No |
NUMBER(10) |
Length | double | Length m |
Actual length of the drill string component | No |
NUMBER |
Linear_Weight | double | Mass_Per_Length kg/m |
Weight of an equipment item per unit length; e.g. Casing weight, pipe weight, cable weight, etc. | No |
NUMBER |
Manufacture_Date | DATE | NA |
Date of manufacturing the facility. | No |
DATE |
Manufacturer | STRING64 | NA |
Name of the business associate who manufactured the item. | No |
VARCHAR2(64) |
Material_Type | STRING64 | NA |
The primary material type of facility. | No |
VARCHAR2(64) |
Max_Differential_Pressure | double | Pressure kPa |
Difference between the test zone pressure below and the borehole pressure above the packer, i.e. draw down or injection pressure | No |
NUMBER |
Max_Dog_Leg_Severity | double | Well_Curvature deg/30m |
The maximum dog leg severity for the tubular. | No |
NUMBER |
Max_Inflated_OD | double | Cylinder_Diameter mm |
Outside diameter of the packer upon inflation, which is the largest suggested hole size for which the packer should be used | No |
NUMBER |
Max_Make_Up_Torque | double | High_Torque kN.m |
The torque above which you have over-torqued (damaged the threads). | No |
NUMBER |
Max_Outside_Diameter | double | Cylinder_Diameter mm |
Maximum external diameter of the tubular. The Outside diameter is the external diameter of the body of the tubular | No |
NUMBER |
Min_Make_Up_Torque | double | High_Torque kN.m |
The minimum torque required to make up the joint to meet the leak resistance spec. | No |
NUMBER |
Model_Name | STRING64 | NA |
Name of a model or version of some entity; for equipment, it may coincide with the trade name. | No |
VARCHAR2(64) |
Name | ENTITY_NAME | NA |
The name given to any object or data item, e.g. name of Well, name of Field, etc. | No |
VARCHAR2(255) |
Non_Magnetic_Flag | boolean | NA |
A flag indicating whether the equipment is made with non magnetic material | No |
NUMBER(1) |
Original_Source | STRING64 | NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
Outside_Diameter | double | Cylinder_Diameter mm |
Actual Outside diameter of the Equipment. For a tubular, it is the outside diameter of the body. In the absence of the actual value the catalog value should be used | No |
NUMBER |
Packer_Inflation_Pressure | double | Pressure kPa |
Sum of the three pressures necessary 1) to match the water pressure above the packer (submergence pressure), 2) to stretch the rubber element out to the borehole, and 3) to seat the packer firmly enough against the well hole to prevent any movement caused by the borehole differential pressure | No |
NUMBER |
Packer_Type | R_Production_Packer |
|
The type of production packer. For example Retrievable, Hydraulic etc. | No |
VARCHAR2(64) |
Polish_Bore_Diameter | double | Cylinder_Diameter mm |
Diameter of polish bore | No |
NUMBER |
Polish_Bore_Length | double | Length m |
The length of polish bore. | No |
NUMBER |
Produced_By | STRING64 | NA |
The name of application role that created the entity, for data created programmatically. | No |
VARCHAR2(64) |
Production_Packer_Spec | R_Production_Packer_Cat |
|
The catalog specification of the production packer. | No |
NUMBER(38) |
Remarks | STRING2000 | NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
SDAT_Label | int | No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
Serial_Number | STRING64 | NA |
The serial number placed on a piece of equipment. | No |
VARCHAR2(64) |
Set_Mechanics_Desc | STRING128 | NA |
Description of the mechanics or procedures required for setting the packer. | No |
VARCHAR2(128) |
Setting_Mechanism | STRING255 | NA |
Description of the mechanism required for setting the packer. | No |
VARCHAR2(255) |
Size_Description | STRING64 | NA |
A textual description of the size of the piece of equipment. For example 8 1/2 inch. | No |
VARCHAR2(64) |
Slip_Desc | STRING128 | NA |
Textual description of the slips above and below the seal element | No |
VARCHAR2(128) |
Source | STRING64 | NA |
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
Steel_Grade | STRING64 | NA |
Grade used to qualify the characteristics of the steel. For tubular, grade determines the minimum yield strength and thus the burst and collapse pressures. The grade can be either defined by the supplier or defined by the API. | No |
VARCHAR2(64) |
Tensile_Strength | double | Pressure kPa |
Maximum tensile strength of the item | No |
NUMBER |
Thread_Lock_Flag | boolean | NA |
A flag to indicate whether or not thread locks have been used | No |
NUMBER(1) |
Torsional_Stiffness | double | Spring_Stiffness N/m |
A measure of the inflexibility of a tubular around its longitudinal axis | No |
NUMBER |
Torsional_Strength | double | Torque N.m |
Maximum torsional strength of the item | No |
NUMBER |
Uninflat_Rubber_Elem_Length | double | Length m |
Affects the "holding power" and sealing ability of the packer. A longer element has more rubber contact against the hole and provides a larger frictional force to support a larger borehole differential pressure. | No |
NUMBER |
Uninflated_OD | double | Cylinder_Diameter mm |
Outside diameter of the packer at rest, which must always be smaller than the hole size for which it will be used. | No |
NUMBER |
Unsetting_Procedure | STRING255 | NA |
Unsetting procedure for the packer. | No |
VARCHAR2(255) |
Update_Date | DATE | NA |
Date of the most-recent modification to the entity. | No |
DATE |
Update_User | STRING64 | NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
Used_Class | STRING64 | NA |
Used Classification (New, used or reconditioned) | No |
VARCHAR2(64) |
VME_Rating | double | No_Unit |
Von Mises Equivalent Stress Rating | No |
NUMBER |
Vendor_Id | Company |
|
The company from which the facility was purchased. | No |
NUMBER(38) |
Version | STRING255 | NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
Wall_Thickness | double | Cylinder_Diameter mm |
The actual thickness of the wall of the tubular. In the absence of the actual value the catalog value should be used | No |
NUMBER |
Weight | double | Force N |
The weight of the Tubular | No |
NUMBER |
Link | To Entity | Description | Implementation Technique | Required |
---|---|---|---|---|
Packer_Type | R_Production_Packer | The type of production packer. For example Retrievable, Hydraulic etc. | Restrict | No |
Production_Packer_Spec | R_Production_Packer_Cat | The catalog specification of the production packer. | Restrict | No |
Catalog_Currency | R_Currency | _ | Restrict | No |
Address | Address | _ | Nullify | No |
Vendor | Company | _ | Nullify | No |