Name | R_Flow_Direction |
---|---|
Entity Type | Table |
Description | Describes whether a fluid flow is flowing in or out. |
Submodel | Reference |
Entity Scope | Reference |
Primary Key | Code |
Natural Key | Code |
Generalizations | Reference_Entity , Reference_Entity_Parent |
Specializations |
Name | Value Domain | Property / Storage Unit | Description | Required / Default | Type |
---|---|---|---|---|---|
Active_Flag | boolean | NA |
1 = use without restriction. 0 = avoid use - the value has been deprecated and may be removed in a later release. | Yes 1 |
NUMBER(1) |
Code | CODE | NA |
A standard abbreviation, mnemonic, or short code that represents the reference value. | Yes |
VARCHAR2(64) |
Description | STRING2000 | NA |
A textual definition of the reference value. | No |
VARCHAR2(2000) |
Insert_Date | DATE | NA |
Date the entity was created in the repository | No |
DATE |
Insert_User | STRING64 | NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
Name | STRING255 | NA |
The spelled-out name of the reference value. | No |
VARCHAR2(255) |
Source | CODE | NA |
The person, company or application that defined or specified the data (content) for this instance and is considered to be responsible for it. For example, POSC, EPSG, API, ISO, etc.. | No |
VARCHAR2(64) |
Update_Date | DATE | NA |
Date of the most-recent modification to the entity. | No |
DATE |
Update_User | STRING64 | NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
From Entity | Link | Description | Implementation Technique | Required |
---|---|---|---|---|
Allocation_Factor_Group | Flow_Direction_Code | A value that describes whether the allocation factor will be applied to fluids flowing in or out of this production entity. | Restrict | Yes |
Fluid_Sample_Acquisition | Flow_Dir_Type | The flow direction of the fluid when the sample was acquired | Restrict | No |
Production_Calc_Pty_Set | Fac_Flow_Direction_Code | Represents whether this production entity is measuring fluid flowing in or out of the production entity (facility) to which it is attached. For example, a meter might measure fluid flowing out of a well. In that case, the flow direction specified in association with that meter would be "out". | Restrict | No |
Production_Volume | Flow_Direction_Code | A value that describes whether the fluid volume represents volume flowing in or out of this production entity. | Restrict | No |
Surface_Fac_Oper_Pty_Set | Flow_Direction_Code | Identified the flow direction in a facility | Restrict | No |
Trace_Hdr_Summary | Flow_Direction_Code | A value that specifies whether the trace originates from material being produced from the well or being injected into the well during the well test stage. Valid values are: In, Out. | Restrict | No |
Well_Test_Fluid_Recovery | Flow_Direction_Code | A value that specifies whether the volume is being produced from the well or being injected into the well during the well test stage. Valid values are: In, Out. | Restrict | Yes |