Name | R_Measurement_Vector_Cat |
---|---|
Entity Type | Table |
Description | The catalog for vector measurement tags with default information |
Submodel | Facility |
Entity Scope | Reference |
Primary Key | Ref_Id |
Natural Key | |
Generalizations | R_Measurement_Tag_Cat , Ref_Entity_Surrogate_Key , Reference_Entity_Parent |
Specializations |
Name | Value Domain | Property / Storage Unit | Description | Required / Default | Type |
---|---|---|---|---|---|
Acquistion_Device_Cat | R_Acquisition_Device_Cat |
|
The type of acquisition device for which this measurement tag is defined. | No |
NUMBER(38) |
Active_Flag | boolean | NA |
1 = use without restriction. 0 = avoid use - the value has been deprecated and may be removed in a later release. | Yes 1 |
NUMBER(1) |
Code | CODE | NA |
A standard abbreviation, mnemonic, or short code that represents the reference value. | No |
VARCHAR2(64) |
Description | STRING2000 | NA |
A textual definition of the reference value. | No |
VARCHAR2(2000) |
Fiber_End_Number | R_Fiber_End |
|
The specific end of the fiber that was used to collect the vector measurement. Valid values are E1 or E2. | No |
VARCHAR2(64) |
IO_Data_Type | R_Data_Type |
|
The data type of the input/output. For example, boolean, integer, float, etc. | No |
VARCHAR2(64) |
Insert_Date | DATE | NA |
Date the entity was created in the repository | No |
DATE |
Insert_User | STRING64 | NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
Measurement_Mode | R_Measurement_Mode |
|
The method that was used to measure the vector tag. For example, temperature measurement, post processing measurement, etc. | No |
VARCHAR2(64) |
Measurement_Process_Code | R_Measurement_Process |
|
The process that was used to obtain the measurement. For example, raw measurement data from the average, raw measurement with background data subtracted, etc. | No |
VARCHAR2(64) |
Measurement_Signal_Code | R_Measurement_Signal |
|
The measurement signal that was used to receive the measurement. For example Temperature sensitive measurement for multi and single mode fibers, or temperature insensitive measurement for multi-mode fiber only, etc. | No |
VARCHAR2(64) |
Measurement_Tag_Type | R_Measurement_Tag |
|
The type associated with the definition of a measurement. | No |
VARCHAR2(64) |
Measurement_Tag_UOM | R_Unit |
|
The unit of measure in which the value for the measurement tag is stored. | No |
VARCHAR2(64) |
Name | STRING255 | NA |
The spelled-out name of the reference value. | No |
VARCHAR2(255) |
Property_Code | R_Property |
|
The property represented by this measurement tag (e.g. Pressure, Temperature) | No |
VARCHAR2(64) |
Read_Write_Indicator | STRING4 | NA |
Read means measurement device, Write means control device. So a device is either a measurement or a control device. | No |
VARCHAR2(4) |
Ref_Id | ID | No_Unit |
The surrogate identifier of an instance of reference data. | Yes |
NUMBER(38) |
Section_Number | R_Fiber_Section_Number |
|
The section of the fiber in which the measurement is acquired. The range is S1..S7. S0 for profiles that are not produced in a section. | No |
VARCHAR2(64) |
Source | CODE | NA |
The person, company or application that defined or specified the data (content) for this instance and is considered to be responsible for it. For example, POSC, EPSG, API, ISO, etc.. | No |
VARCHAR2(64) |
Storage_Unit_System | R_Unit_System |
|
The unit system in which the numeric values are stored. It is expected that every numeric value in this table will be of the same unit system e.g Metric, English etc | No |
VARCHAR2(64) |
Typical_Source | CODE | NA |
A string to denote whether this tag is usually associated with a well, a facility or another entity. | No |
VARCHAR2(64) |
Update_Date | DATE | NA |
Date of the most-recent modification to the entity. | No |
DATE |
Update_User | STRING64 | NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
Version | CODE | NA |
A string to represent the version assigned to this particular tag configuration. | No |
VARCHAR2(64) |
From Entity | Link | Description | Implementation Technique | Required |
---|---|---|---|---|
Measurement_Tag_Vect_Conf | Config_Cat | The default catalog entry for this tag configuration | Restrict | No |
Link | To Entity | Description | Implementation Technique | Required |
---|---|---|---|---|
Fiber_End_Number | R_Fiber_End | The specific end of the fiber that was used to collect the vector measurement. Valid values are E1 or E2. | Restrict | No |
Measurement_Mode | R_Measurement_Mode | The method that was used to measure the vector tag. For example, temperature measurement, post processing measurement, etc. | Restrict | No |
Section_Number | R_Fiber_Section_Number | The section of the fiber in which the measurement is acquired. The range is S1..S7. S0 for profiles that are not produced in a section. | Restrict | No |
Measurement_Signal_Code | R_Measurement_Signal | The measurement signal that was used to receive the measurement. For example Temperature sensitive measurement for multi and single mode fibers, or temperature insensitive measurement for multi-mode fiber only, etc. | Restrict | No |
Measurement_Process_Code | R_Measurement_Process | The process that was used to obtain the measurement. For example, raw measurement data from the average, raw measurement with background data subtracted, etc. | Restrict | No |
Storage_Unit_System | R_Unit_System | _ | Restrict | No |
Measurement_Tag_UOM | R_Unit | _ | Restrict | No |
Measurement_Tag_Type | R_Measurement_Tag | _ | Restrict | No |
IO_Data_Type | R_Data_Type | _ | Restrict | No |
Acquistion_Device_Cat | R_Acquisition_Device_Cat | _ | Restrict | No |
Property_Code | R_Property | _ | Restrict | No |