Measurement_Tag_Scal_Conf


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Measurement_Tag_Scal_Conf
Entity Type Table
Description The configuration of a type of scalar measurement. A scalar value is represented by a single value.
Submodel Facility
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Measurement_Tag , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue DomainProperty /
Storage Unit
DescriptionRequired /
Default
Type
Acquisition_Device_Id Acquisition_Device
The control device for the measurement tag where the value of the measurement tag is recorded or set. No
NUMBER(38)
Acquisition_Frequency double No_Unit
Frequency of acquisition between the devices and the acquisition sub system No
NUMBER
Channel_Address STRING64 NA
Address of the channel on the device. For example the modbus address No
VARCHAR2(64)
Config_Cat R_Measurement_Scal_Cat
The default catalog entry for this tag configuration No
NUMBER(38)
End_Date DATE NA
End of service No
DATE
Existence_Kind REF_EXISTENCE_KIND NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
GUID STRING128 NA
Globally Unique IDentifier for an instance of a class. USAGE NOTES: There are two cases: 1) GUID is not populated or used; and 2) it is populated with a value that is globally unique. If the GUID is populated there are two means of doing so for a given project: 2a) Seabed automatically generates and populates the GUID when an instance is created (valid only on Oracle based systems); and 2b) the GUID is generated and populated by an application (other than Seabed) on instance creation. Whether Seabed automatically generates GUIDs for a project is determined by the Auto_GUID flag in SDS_Account. Note that techniques 2a and 2b can coexist in the same project. When GUIDs are automatically generated an application can override the automatically generated GUID with its own GUID by simply supplying the GUID value. Applications that generate their own GUIDs and populate the GUID column will function correctly on projects which have automatic GUID generation turned on. No
VARCHAR2(128)
IO_Data_Type R_Data_Type
The data type of the input/output. For example, boolean, integer, float, etc. No
VARCHAR2(64)
Id ID No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE NA
Date the entity was created in the repository No
DATE
Insert_User STRING64 NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Measurement_Point_Id Measurement_Point
Location of the measurement tag No
NUMBER(38)
Measurement_Tag_UOM R_Unit
The unit of measure in which the value for the measurement tag is stored. No
VARCHAR2(64)
Name ENTITY_NAME NA
The name given to any object or data item, e.g. name of Well, name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64 NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Produced_By STRING64 NA
The name of application role that created the entity, for data created programmatically. No
VARCHAR2(64)
Raw_High_Value double No_Unit
The maximal value possible for the raw value (as it is acquired from the device) of the scalar tag. No
NUMBER
Raw_Low_Value double No_Unit
The minimal value possible for the raw value (as it is acquired from the device) of the scalar tag. No
NUMBER
Read_Write_Indicator STRING4 NA
Read means measurement device, Write means control device. So a device is either a measurement or a control device. No
VARCHAR2(4)
Register_Address STRING64 NA
Equipment register No
VARCHAR2(64)
Remarks STRING2000 NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Scale_High_Value double No_Unit
The maximum value possible for the scaled value (the value in the real physical scale) of the scalar tag. No
NUMBER
Scale_Low_Value double No_Unit
The minimal value possible for the scaled value (the value in the real physical scale) of the scalar tag. No
NUMBER
Sensor_Id Sensor
The sensor which measured this tag. No
NUMBER(38)
Source STRING64 NA
Name of the person or organization responsible for this entitys E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Start_Date DATE NA
Start of service No
DATE
Transmission_Frequency double No_Unit
Frequency pollset No
NUMBER
Update_Date DATE NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64 NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255 NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Config_Cat R_Measurement_Scal_Cat The default catalog entry for this tag configuration Restrict No
Measurement_Tag_UOM R_Unit _ Restrict No
Sensor Sensor _ Nullify No
IO_Data_Type R_Data_Type _ Restrict No
Acquisition_Device Acquisition_Device _ Cascade No
Measurement_Point Measurement_Point _ Restrict No


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2018 Schlumberger. All rights reserved.